This paragraph anesthesia machine adopts advanced and stable APL valve device, suitable for low flow anesthesia, color LCD screen, can display time pressure, flow time and pressure-volume loop, with oxygen concentration monitoring, and optional plug-in patient monitoring, composition anesthesia workstation.
Features:
Anesthesia ventilator
Pneumatically driven electronically controlled system
Built-in ventilator, 10.4" LCD display
With 1 patient circuit for adult (Optional:patient circuit for children)
5-tube flowmeters, O2 & N2O & Air;0.1L/Min ~ 10 L/Min;
Two vaporizers,Enflurane/Isoflurane/Sevoflurane; (Optional: Halothane)
Oxygen Flush: 25~75 L/Min;
Respiration Mode: IPPV, SIPPV(VCV), IMV,SIMV, PEEP, Manu, Sigh
Tidal Volume: 0~1500 mL;I:E: 8:1~1:10
Respiration Frequency: 1~99bpm;
PEEP: 1~10 hPa;
Ptr: -10~10 hPa;
CO2 absorber capacity: 1 kg
Lung compliance: ≤ 30mL/kPa;
IMV frequency: 1~12bpm
Inspiratory Plateau: 0~1S;
O2 Concentration: 21%~100%
Alarm parameter: upper /lower limit ofairway pressure, tidal volume exceed limitation, no tidal volume output, apnea,AC power malfunction, battery low power
Patient Monitor
12.1''TFT large screen of high resolution
ECG: 5-lead, gain:×2.5mm/mV ×5.0mm/mV×10mm/mV ×20mm/mV, analysis of ST segment and abnormal of heart rate(anti-defibrillate, anti-HF electrotome)
Heart Rate: 20~250bpm
RESP: Impedance, range: 0~100bpm
SpO2: 0%~100%
Pulse Rate: 20~250bpm
NIBP: SBP, DBP, MBP, 10~270mmHg interval ofautomatic measurement 1~90min adjustable
TEMP: 0~50ºC
Alarm: Audio and visual alarm
Tendency record 96 hours
Loop part
Integrated design, integrated breathingcircuit
Evaporator
High-precision double evaporators configuration, enflurane or isoflurane or Sevflurane or Haloflurane
Concentration adjustment range: 0.5 ~ 5%VOL
Evaporator flow, pressure, and automatictemperature compensation function
Self-locking feature
Configuration
Vaporizer: Two vaporizers, Enflurane/Isoflurane/Sevoflurane(Option: Halothane)
Anesthesia gas concentration range: 0.5~5%
Soda lime absorption system: resistance tohigh temperature of 176 degrees Celsius.
ISO certificates approved
Model | THR-850 (Standard Model) | THR-850 (High end Model) |
Display | 8.4 inch TFT display | 10.4 inch TFT display |
Flowmeter Range | O2: 0.1-10L/min | |
N2O: 0.1-10L/min | ||
Air: 0.1-10L/min | ||
Ventilation Mode | IPPV, SIPPV, VCV, IMV, SIMV, MANUAL, Standby | IPPV, SIPPV, VCV, PCV, IMV,SIMV, MANUAL, Standby |
Back-up Power Supply | At least 4 hours | |
Tidal Volume | Adjustable range: 10-1500ml | |
Display range: 0-2000ml | ||
Respiratory Rate | 1-100bpm | |
Inspiratory/Expiratory (I:E) Ratio | 8:1-1:10 (capable of inverse ratio ventilation) | |
PEEP Range | 0-20cmH2O (electronically controlled) | |
Inspiratory Pressure Trigger Range | -10-10cmH2O (electronically controlled) | |
SIGH | 1 sigh breath in every 80-120 breaths | |
Inhaled Oxygen Concentration Monitor | 21-100% | |
SIMV Rate | 1-20bpm | |
Inspiratory Plateau | 0-1 second | |
Vaporizer Concentration Ranges | 0-5% | |
Vaporizer Slots | Double PA-I type slots |