First Aid Biphasic Defibrillator Monitor (DM7000)

Model NO.
DM7000
Warranty
12 Months
Application
First-Aid Devices
Display
7′′ Color Display
Product Name
Defibrillator / Aed Dedibrillator
Transport Package
Strong Packing
Specification
CE, ISO, TUV
Trademark
PIOWAY
Origin
China
HS Code
9018909919
Production Capacity
5000 Units/Month
Reference Price
$ 1,863.00 - 2,070.00

Product Description

First Aid Biphasic Defibrillator Monitor (DM7000)

First Aid Biphasic Defibrillator Monitor (DM7000)

Product Brief
DM7000 is a defibrillation device, which can meet your clinical needs from Basic Life Support (BLS) to Advanced Cardiac Life Support (ACLS). 

Feature
7" Color Display, Waveform: Biphasic
Charge Time: Less than 7 seconds
Rechargeable Battery, 60 discharges at max
energy, with SPO2 module

Technical Parameters
Display 
Screen Type High-resolution display
Screen Size 7 inches(17.7 cm) diagonally 
Sweep Speed 25mm/sec 
Information Heart Rate, Lead/Pads, Alarm On/Off, SpO2, AED Functions and Prompts, Alarm Selection and Limits, Delivered Energy. 
Defibrillator
Waveform Biphasic 
Charge Time Less than 7 seconds with a new fully charged battery. 
Energy Display Monitor display indicates both selected and delivered energy. 
Charge Prompt Type Voice and visual prompts. 
Electrode Impedance Measurement Range 0-250 ohms. 
ECG Monitoring  
Patient Connection 3-lead ECG cable, or 5-lead ECG cable, paddles. 
Lead Selection Displayed on monitor, paddles, I, II, III, AVR, AVL, AVF, V. 
ECG Size 0.25, 0.5, 1, 1.5, 2, 4 cm/mV diplay on monitor. 
Heart Rate 20-300BPM. 
Heart Rate Alarm On/Off displayed on monitor, user-selectable. 
Smart Alarms Beeper/voice prompts indicate shockable rhythm. 
Battery
Type Rechargeable, Ni-MH battery, 12V. 
Operating Time For a new, fully charged battery: 60 defibrillator discharges at maximum energy, or 3 hours minimum of continuous ECG monitoring. Additional parameters will effect operating time with different functions. 
SpO2 Module  
Measurement Range 30~100%, ±2% between 80%~90%, others ±5% 
Alarm Range User set high limit and low limit. 
Alarm Accuracy ±10% within setting values. 
Alarm time Accuracy less than 12 sec.
Recorder  
Paper 50mm thermal. 
Speed 12.5mm/sec, 25mm/sec, 50mm/sec. User-selectable 6-second delay. 
Printing Method High-resolution, thermal print head. 
Print-out Modes Manual or automatic, user-configurable. 
On/Off Control Front panel and paddle. 
Automatic Function 9-seconds recording initiated by alarm activation or defibrillator charge or defibrillator discharge. 
AED Mode 
AED Function Auto analyze and charge x3 with programmable auto energy level selection, screen prompts, and voice prompts. 
Shockable Rhythms Ventricular fibrillation with amplitude >=200uV,
Ventricular tachycardia with rates >=140bpm,
and QRS complex wave duration >=140ms. 
Charge Control Control on device front panel, press key on paddle. 
Prompts Voice and visual prompts. 
Manual Mode 
Energy Selection Selectable at 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 joules. 
Synchronized Mode Synchronizes defibrillator pulse to patient's R-wave. "SYNC" message displayed on monitor.

Detailed Images