| Specifications for defibrillator | |
| Display | |
| Display Type | 7 inch high resolution LCD display |
| Sweep Speed | 25mm/sec |
| Information |
HR, Lead/Pads, On/Off Alarm , SpO2,
AED Functions and Prompts, Alarm Selection and Limits, Delivered Energy. |
| Below is feature | |
| Waveform | Biphasic |
| Charge Time | Less than 7 seconds with a new fully charged battery. |
| Energy Display | Monitor display indicates both selected and delivered energy. |
| Charge Prompt Type | Voice and visual prompts. |
| Electrode Impedance Measurement Range | 0-250 ohms. |
| ECG Monitoring for Defibrillator | |
| Patient Connection | 5-lead ECG cable, or 3-lead ECG cable, paddles. |
| Lead Selection | Displayed on monitor, paddles, I, II, III, AVR, AVL, AVF, V. |
| ECG Size | 0.25, 0.5, 1, 1.5, 2, 4 cm/mV diplay on monitor. |
| Heart Rate | 20-300BPM. |
| Heart Rate Alarm | On/Off displayed on monitor, user-selectable. |
| Smart Alarms | Beeper/voice prompts indicate shockable rhythm. |
| SpO2 Module | |
| Measurement Range |
30~100%,
± 2% between 80%~90%, others ± 5% |
| Alarm Range | User set high limit and low limit. |
| Alarm Accuracy | ± 10% within setting values. |
| Alarm time Accuracy | Less than 12 sec. |
| Recorder | |
| Paper | 50mm thermal. |
| Speed |
12.5mm/sec, 25mm/sec, 50mm/sec.
User-selectable 6-second delay. |
| Printing Method | High-resolution, thermal print head. |
| Print-out Modes | Manual or automatic, user-configurable. |
| On/Off Control | Front panel and paddle. |
| Automatic Function |
9-seconds recording initiated by alarm activation or
defibrillator charge or defibrillator discharge. |
| Battary | |
| Type | Rechargeable, Ni-MH battery, 12V. |
| Operating Time | For a new, fully charged |
| battery |
60 defibrillator discharges at maximum energy,
or 3 hours minimum of continuous ECG monitoring. Additional parameters will effect operating time with different functions. |
| AED Mode | |
| AED Function |
Auto analyze and charge X3 with programmable auto energy level selection,
screen prompts, and voice prompts. |
| Shockable Rhythms |
Ventricular fibrillation with amplitude >=200UV,
ventricular tachycardia with rates >=140bpm, and QRS complex wave duration >=140ms. |
| Charge Control | Control on device front panel, press key on paddle. |
| Prompts | Voice and visual prompts. |
| Manual Mode | |
| Energy Selection | Selectable at 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 joules. |
| Synchronized Mode |
Synchronizes defibrillator pulse to patient's R-wave.
"SYNC" message displayed on monitor |
| Model | DM7000 |
| Brief Introduction | biophasic AED defibrillator,7" LCD |
| Patient Monitor |
ECG,HR, Lead/Pads, On/Off Alarm, SpO2, AED Functions and Prompts, Alarm Selection and Limits, Delivered Energy. |