M100 Low Price Simple Operation Single Phase AC Variable Frequency Inverter 2.2kw AC Drive
1.General Specifications
Inverter Series | M100 | |
Control Mode | SPWM | |
Input Power |
380V Power supply: 380±15% 220V Power supply:
220±15% |
|
4-Digits Display & Status
Indicator Lamp |
Displaying frequency, current, revolution, voltage, counter,
temperature, forward or reserve running, and fault, etc. |
|
Communication Control | RS-485 | |
Operation Temperature | -10~40ºC | |
Humidity | 0-95% Relative Humidity (without dew) | |
Vibration | Below 0.5G | |
Performance and Motor Control |
Range | 0.10~600.00Hz |
Accuracy | Digital: 0.01% (-10-40ºC) ; Analog: 0.1% (25±10ºC) | |
Setting Resolution | Digital: 0.01Hz; Analog: 1%o of Max. Operating Frequency | |
Output Resolution | 0.01Hz | |
Keyboard Setting Method | Press directly to set | |
Analog Setting Method | External Voltage 0-5V, 0-10V, 4-20mA,0-20mA | |
Other Functions |
Frequency lower limit, starting frequency, stopping frequency,
three skip frequencies can be respectively set. |
|
Ramp Control | Selectable 4-speed steps ramp-up and down time (0.1-6500s). | |
V/F Curve | Set V/F curve at will | |
Torque Control |
Torque increase is settable by max. 10.0%. The starting torque
can reach 150% at 1.0Hz. |
|
Multi-Inputs |
6 multi-function input terminals for 8-speed steps control,
program operation, switching of 4-speed Ramp, UP/DOWN function, counter, external emergency stop and other functions. |
|
Multi-Outputs |
1 multi-function output terminals for displaying of running, zero
speed, counter, external abnormity, program operation and other information and warnings. |
|
Other Functions |
AVR (auto voltage regulation), Deceleration stop or free-stop,
DC brake, auto reset and restart, frequency track, PLC control, traverse function, drawing control, auto energy-savings, carrier adjustable by max. 16KHz, etc. |
|
Protection |
Overload Protection |
Electronic relay protection motor
Drive (for constant torque 150%/1 min; for the kinds of fan 120%/1min.) |
FUSE Protection | FUSE broken, motor stops. | |
Over-voltage |
DC Voltage > 400V for 220V class
DC Voltage > 800V for 380V class |
|
Low Voltage |
DC Voltage < 130V for 220V class
DC Voltage < 300V for 380V class |
|
Instant Stop and Restart | Restarted by frequency track after instantaneous stop. | |
Stall Prevention | Anti-stall during Acc/Dec run | |
Output End Shorts | Electronic circuit protecting | |
Other Functions |
Fin over-heat protection, restriction of reverse running, direct
start after power on, fault reset, parameter lock PID, one-drive-more, etc. |
2.Label Information:
3.Type Difination:
4.Dimension:
5.Keypad Information:
6.Product Show: