M odel No. | W avelength | Dynamic R ange | Max. Test R ange |
TOT560-A24D | 1310/1550 nm | 24/22 dB | 80 km |
Measuring range | 100m ,500m,2km,5km,10km,20km,40km,80km /90km | ||
Sampling resolution | Minimum : 0. 2 m | ||
Event dead zone | < 2.0m | ||
Attenuation dead zone | < 7.0m | ||
The sampling point | 64 ,000 point | ||
L inearity | ≤ 0.05dB/dB | ||
Loss threshold | 0.01dB | ||
Loss resolution | 0.001dB | ||
Range resolution | 0.01m | ||
Range accuracy | ± ( 0.5 m+ Range ×3×10 -5 +Sampling resolution) (Excluding refractive index error) | ||
Memory | >40000 | ||
Data interface | 2 USB ( Type A × 1 , Micro USB × 1 , SD card ) | ||
S creen | 4.3-inch TFT-LCD (Standard distribution capacity touch screen) | ||
Battery | 3.7V/5200mAh | ||
T emperature |
Working temperature
:
-
10
ºC~+
55
ºC
;
Storage temperature: - 20 ºC~+ 80 ºC |
||
H umidity | ≤95% ( No condensation ) | ||
Size/Weight | 175x105x45mm / 0.56 kg ( Include the battery) | ||
OPM | Type A: + 10dBm~-70dBm;Type B:+26dBm~-50dBm | ||
VFL | 10mW,CW/2Hz | ||
LS( Laser Source ) | The output power:-5dBm,Modulation frequency:CW/270Hz/1KHz/2KHz | ||
Network Cable test
(Optional) |
Support network wire sequence testing and wire alignment |
Standard |
FC adaptor, Power adapter,
L
ithium battery, USB cable,
Q uick guide, P ortable package |