| Item | Content | Criterion |
| OVC | Over charge detection voltage | 4.250±0.050V |
| Detection delay time | 1.0±0.3S | |
| Over charge release voltage | 4.150±0.050V | |
| OVD | Over discharge detection voltage | 2.700±0.080V |
| Detection delay time | 1.0±0.3S | |
| Over discharge release voltage | 3.000±0.100V | |
| Rated operational current | ≤20A | |
| OCD | Primary over current detection current | 50±5A |
| Primary detection delay time | 800mS-1200mS | |
| Secondary over current detection curren | 100±10A | |
| Secondary detection delay time | 50mS-200mS | |
| Short protection | Detection condition | >200A, 200uS-300uS |
| Protection | yes Exist | |
| Protective release condition | Disconnect short circuit | |
| Charging management | Charging overvoltage protection voltage | 43.5±0.4V |
| Rated charging current | 3A | |
| Software overcharges | 4±0.2A | |
| Detection delay time | 300mS-600mS | |
| Temperature protection | Charging high temperature protection temperature | 50±4ºC |
| Charging protection recovery temperature | 47±4ºC | |
| Discharge high temperature protection temperature | 70±4ºC | |
| Discharge protection recovery temperature | 55±4ºC | |
| Low temperature protect temperature of charging | 0±4ºC | |
| Low temperature recovery temperature of charging | 5±4ºC | |
| Interior resistance | Main loop electrify resistance | ≤60mΩ |
| The static current | Since the power consumption | ≤60.0uA |
| NTC | YES Exist | 10K±1% B3435±1% |