| Item | Item Description | |
| Input | Rated voltage& Frequency | Single /Three phase 220VAC . Three phase 380V.50Hz/60Hz |
| Allowable Voltage range |
Voltage fluctuate range:-20%~+20%
Voltage unbalance rate:<3%;Frequency fluctuation:≤5% |
|
| Output | Rated voltage | three phase 0~ input AC voltage |
| Frequency | 0.00~600.00Hz | |
| Overload capacity |
Type G:150% 1minute,180% 1 second,200% transient protection
Type P:120% 1minute,150% 1 second,180% transient protection |
|
| Control Function | Modulation mode |
Optimal space voltage vector PWM modulation
|
| Control mode |
Sensorless vector control (SVC), V/F control . Torque control
|
|
|
Frequency accuracy
|
Digital setting::Max. Frequency×±0.01%
Analog setting:Max. Frequency×±0.2% |
|
| Frequency resolution |
Digital setting :0.01HZ;
Analog setting :Max. Frequency x0.1%. |
|
| Starting frequency | 0.00~10.00Hz | |
| Torque lift |
Automatic torque lift: To lift the torque automatically according to the output current.
Manual torque lift, Range: 0.1_30.0% |
|
| Slip compensation | Setting range:0~150%,The inverter output frequency can be auto-regulated within this range according to the motor load, so as to reduce the speed variation of the motor due to load fluctuation. | |
|
Acceleration/deceleration
time |
Minutes/Seconds can be selected as time unit .0.1~3600 can be set in sequence . | |
| Carrier frequency | 1.0~15.0KHz | |
| Jog function |
Jog frequency range:0.01~600.00Hz,
Jog acceleration /deceleration time 0.1~3600.0 can be set. |
|
| V/F curve | 1:linear curve;2:quadratic;3:user defined V/F curve | |