| INERTER MODEL | HS-INV-SPH5K |
| PV INPUT | |
| Max. PV Input Power | 10kW |
| Max. PV Input Voltage | 580V |
| MPPT Range | 100~550V |
| Max. Input Current | 15A/15A |
| Max. Short Circuit Current | 18.75A/18.75A |
| MPPT Trackers | 2 |
| Strings Per MPPT Tracker | 1/1 |
| AC PORT | |
| Rated Grid Output Power | 5kVA/4.6kVA(DE) |
| Max. Grid Input Power | 10kVA |
| Rated Grid / Backup Voltage | 230Vac |
| Rated Grid / Backup Frequency | 50/60Hz |
| Max. Backup Power | 10kVA/10kW |
| THDi | <3% |
| THDv | <3% (Linear Load) / <5%(Non-linear Load) |
| DCV | <100mV |
| Crest Ratio | 3:01 |
| Transfer Time | <10ms |
| EFFICIENCY | |
| Max. Efficiency | 97.30% |
| Round Trip Efficiency | 90% |
| GENERAL DATA | |
| Operating Temperature Range | -20~60ºC |
| Topology | Transformerless |
| Dimensions (W*H*D) | 590×405×205mm |
| Weight | 19.5kg |
| Load Monitoring | Meter / CT / Backup box |
| External Communication | RS-485 / WIFI / 4G / Ethernet |
| Grid Regulation | CEI 0-21, VDE 4105-AR-N, VDE 0126-1-1, EN 50438, G99, G100, AS4777.2 |
| NRS 097, EN 50549, C10/C11, UNE, UTE, NCRfG/PTPiREE | |
| Safety Regulation | IEC 62109-1&2,IEC 62477 |
| BATTERY MODEL | HS-BAT-10.1P |
| Battery Type | LFP |
| Battery Capacity | 10.1kWh |
| Usable Capacity | 9.6kWh |
| Depth of Discharge (DoD) | 95% |
| Nominal Battery Voltage | 96V |
| Operating Voltage Range | 90~108V |
| Max. Charging Current | 52.5A |
| Max. Discharging Current | 52.5A |
| Operating Temperature Range | Charge:0<T<50ºC / Discharge:-10<T<50ºC |
| Cycle Lifetime | 8000 |
| Parallel | 1~6 |
| Dimensions (W*H*D) | 590×750×205mm |
| Weight | 90kg |
| Communication | CAN / RS-485 (Optional) |
| Safety Regulation | IEC 62619, IEC 62040 |
| Transportation | UN38.3 |
| SYSTEM | |
| Operating Altitude | ≤4000m |
| Relative Humidity | 0~95% (No Condensing) |
| Protection Degree | IP65 |
| Cooling | Natural Convection |
| Noise | <30dB |
| Warranty | 5 years / 10 years (optional) |
| EMC | EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4 |