DSC-300C Mechanical Cooling Scanning Differential Scanning Calorimetry Tester
Product Description
Product Name |
DSC-300C Mechnical Cooling Scanning Differential Scanning Calorimetry Tester with Good Linear Curve DSC Manufacturer |
Applications |
High polymer material industry; High-molecular polymer industry; University; Educational Institutions; Lab; Research Institute ETC... |
Function |
Oxidation induction time (OIT); Glass transition (Tg); Melt; Crystal; Thermal Stability; Curing / Crosslinking; Cold Crystal; Phase Transition. ETC... |
Standards |
ISO/TR10837:1991, ASTM D3895-1998, ASTM E 967, ASTM E 968, ASTM E 793, ASTM D 3895, ASTM D 3417, ASTM D 3418, ISO 11357-6 ETC... |
Model Selection
Model |
DSC-100 |
DSC-100L |
DSC-300 |
DSC-300L |
DSC-300C |
Temperature Range |
RT ~ 800ºC |
-100 ~ 800ºC |
RT ~ 550ºC |
-150 ~ 600ºC |
-40 ~ 600ºC |
DSC Range |
0~± 600mW |
0~± 600mW |
0~± 600mW |
0~± 600mW |
0~± 800mW |
Cooling Method |
Air Cooled |
Liquid Nitrogen Cooled |
Air Cooled |
Liquid Nitrogen Cooled |
Mechanical Cooled |
Scanning Method |
Heating Scan |
Heating Scan |
Heating Scan + Cooling Scan |
Product Description
Summary:
Ø
The Differential Scanning Calorimeter DSC refers to in the temperature control program and a certain atmosphere, measuring the temperature difference between the sample and the reference material is proportional to the rate of heat flow through the thermal plate instrument.
Ø
the relevant differential scanning calorimeter technical specifications can be found in the National Metrology regulations (JJG936-1998).
Ø
DSC have two main types: the power compensation and heat flux.
Ø
Our DSC is heat flow differential scanning calorimeter.
Ø
DSC is widely used in the field of polymer development, performance testing & quality control.
Standard:
ISO/TR10837:1991, ASTM D3895-1998, ASTM E 967, ASTM E 968, ASTM E 793,
ASTM D 3895, ASTM D 3417, ASTM D 3418, ISO 11357-6 ETC...
Features:
1. The industrial-grade 7-inch touch screen displays rich information.
2. Brand-new metal furnace body structure, with better baseline and higher accuracy. The heating adopts indirect conduction method, which has high uniformity and stability, reduces pulse radiation, and is better than traditional heating mode.
3. USB communication interface, strong versatility, reliable and uninterrupted communication, supports self-recovery connection function.
4. Automatically switch the two-channel atmosphere flow, fast switching speed and short stabilization time. At the same time, a protective gas input is added.
5. The software is simple and easy to operate.
Differential Scanning Calorimeter
DSC is designed to determine the inner heat transition relating to temperature and heat flow, it is widely used in the field of polymer development, performance testing & quality control. DSC research and development includes the following field: glass transition temperature, melting point, cold crystallization, crystallization, phase transition, oxidation induction time (OIT).
Features of DSC-300C Differential Scanning Calorimeter
1. The industrial-grade 7-inch touch screen displays rich information.
2. Brand-new metal furnace body structure, with better baseline and higher accuracy. The heating adopts indirect conduction method, which has high uniformity and stability, reduces pulse radiation, and is better than traditional heating mode.
3. USB communication interface, strong versatility, reliable and uninterrupted communication, supports self-recovery connection function.
4. Automatically switch the two-channel atmosphere flow, fast switching speed and short stabilization time. At the same time, a protective gas input is added.
5. The software is simple and easy to operate.
6.
Mechanical cooling via low temperature thermostatic bath, better controlled with good linear curve. It can be reused to save costs than liquid nitrogrn.
Model | DSC-300 | DSC-300L | |
DSC Range | 0~± 600mW | 0~± 600mW | |
Temperature Range |
RT ~ 550ºC
(Air Cooling) |
-150 ~ 600ºC
(Liquid Nitrogen Cooling) |
|
Heating Rate | 0.1~80ºC/min | 0.1~80ºC/min | |
Temperature Resolution | 0.001ºC | 0.001ºC | |
Temperature Fluctuation | ±0.001ºC | ±0.001ºC | |
Temperature Repeatability | ±0.1ºC | ±0.1ºC | |
DSC Noise | 0.01μW | 0.01μW | |
DSC Resolution | 0.01μW | 0.01μW | |
DSC Accuracy | 0.01mW | 0.01mW | |
DSC Sensitivity | 0.01mW | 0.01mW | |
Temperature Control Mode |
Rising Temp, Constant Temp, Cooling Temp
(Full Automatic Programmed Control) |
||
Curve Scanning | Heating Scan + Cooling Scan | ||
Atmosphere Control Gas | Nitrogen, Oxygen (Switch Automatically) | ||
Gas Flow Rate | 0-300mL/min | 0-300mL/min | |
Gas Pressure | 0.2MPa | 0.2MPa | |
Display method | 7-inch LCD Touch Screen | 7-inch LCD Touch Screen | |
Communication Interface | Standard USB interface | Standard USB interface | |
Parameters Standard | Equip with Standard Materials (INDIUM, TIN) | ||
Software | 4 in 1 operating software | ||
Thermocouple |
Total 3 sets of thermocouples for:
1). Test Sample Temperature 2). Test Furnace Temperature, 3). Test Internal Ambient Temperature |